Solar Savings Calculator

GEES • ENERGY PLANNING

See what solar could save you.

Start with the monthly consumption on your electricity bill. Explore solar and battery options, then request a solution designed for your property.

All amounts are Guyana dollars (G$). Estimates, not a quotation or final system design.

Use an average of several bills where possible. Enter energy used, not the amount owed or an outstanding balance.

Reference rates come from GPL’s published tariff table dated April 11, 2021. Check your current bill and overwrite these values if different. This estimate holds the selected rate and retained charges constant; it does not recalculate tariff eligibility, taxes or demand charges.

Generation, export and cost assumptions

130 is an illustrative planning assumption, not a site-specific forecast. Adjust for location, roof orientation, shading and system losses. The model uses average daily energy; it does not simulate hourly weather or load.

Only include export credits for an approved, export-capable system. Enter the rate in your agreement. Credits offset energy charges only; surplus credit banking and annual payouts are excluded.

Enter your details and select Calculate my savings.

Solar without a suitable backup system normally shuts down during a grid outage. Battery backup alone is primarily for continuity; grid charging losses can increase consumption.
Request a GEES assessment

Bring your recent electricity bills and these results. GEES can confirm sizing, equipment, roof suitability, installation costs and grid-connection requirements.

How the estimate works

Solar generation equals panel capacity multiplied by the monthly yield assumption. Solar first serves the estimated daytime load. For solar plus storage, surplus solar may charge the usable battery up to one cycle per day; 90% of charged energy can meet remaining nighttime demand. This simplified average-energy model may overestimate savings where real-time loads and generation do not align, or outages limit generation. Battery losses are counted once. No grid charging is assumed for the hybrid savings estimate. Backup runtime is a separate full-charge scenario and is not guaranteed simultaneously with maximum savings.

Annual operating savings equal twelve times the monthly bill reduction less the maintenance allowance. Simple payback uses the entered installed price and positive annual operating savings. Finance costs, battery replacement, degradation, changing tariffs and exceptional weather are excluded. Off-grid and generator fuel comparisons require a separate GEES assessment.

Sources: GPL tariff reference · GPL grid connection and net billing. Assumptions reviewed November 24, 2026.